NDIR-SF6-200
Update time:Feb-02-19
Performance Characteristics Sensor principle non-dispersive infrared (NDIR) Measurement range 0 ~ 200 ppm SF6 Resolution 60 ppb Response time 1 second (Responsible) 12 seconds (@500 ml/min) Recovery time 12 seconds (@500 ml/min) Recovery ti
Performance Characteristics
Sensor principle |
non-dispersive infrared (NDIR) |
Measurement range |
0 ~ 200 ppm SF6 |
Resolution |
< 60 ppb |
Response time |
< 1 second (Responsible) |
|
< 12 seconds (@500 ml/min) |
Recovery time |
< 12 seconds (@500 ml/min) |
Recovery time |
≤ 10 seconds @500 ml/min |
Long-term stability |
being tested |
Tolerance |
±100 ppb (0 ~ 10ppm) |
|
±2 ppm (10 ~ 100ppm) |
Reading unit |
ppb |
Detection limit |
100 ppb |
Environmental
Temperature Range |
0ºC ~ 40ºC |
Pressure Range |
1 atm ± 50% |
Humidity Range |
0 % ~ 85 % RH non-condensing |
Flow rate |
300 ~ 800 ml/min |
Life Time
Storage temperature |
-20 ℃ ~ 50 ℃ |
Operating lifetime |
> 5 years |
Storage life |
> 5 years |
Warranty |
18 months |
Electrical
Supply voltage |
9 ~ 24 VDC(Pin #9) |
Working current |
< 150 mA at 9 VDC |
Power consumption |
< 1.0 W Average |
|
< 1.5 W @ peak |
Warm-up time |
3 min (Tolerance ± 1 ppm) |
|
60 min (Tolerance ± 100 ppb) |
Output voltage |
NR |
Mechanical
Optical path |
Stainless steel |
Weight |
540 grams |
Approvals
Pending